Back to top
Diesel Engine Fire Pump
Diesel Engine Fire Pump

Diesel Engine Fire Pump

MOQ : 1 Set

Diesel Engine Fire Pump Specification

  • Voltage
  • 24V DC (for control), engine powered
  • Mounting Type
  • Base Frame Mounted
  • Technology
  • Centrifugal Pump Technology
  • Installation Type
  • Floor Mounted
  • Energy Efficiency Rating
  • High Efficiency
  • Working Temperature
  • -10C to 60C
  • Coverage Area
  • Large Scale Facilities
  • Fire Extinguisher Type
  • Pumping System for Hydrants/Sprinklers
  • Coating Type
  • Epoxy Powder Coated
  • Operating Pressure
  • 10-12 bar
  • Control Type
  • Automatic / Manual Panel Control
  • Connectivity Type
  • Hardwired System Integration
  • Shape
  • Horizontal Split Case
  • Fire Class
  • Class A, B & C Fires
  • Features
  • High Efficiency, Reliable Diesel Backup, Corrosion Resistant, Easy Maintenance
  • Application
  • Industrial and Commercial Fire Protection
  • Max Flow Rate
  • 3000 LPM
  • Capacity
  • Up to 3000 LPM
  • Diameter
  • 100 mm
  • Pressure
  • Up to 12 bar
  • Drive Type
  • Direct Coupled
  • Noise Level
  • 85 dB at 1 meter
  • Suction/Discharge Size
  • 100 mm / 80 mm (customizable)
  • Engine Type
  • Water-cooled Diesel Engine
  • Automatic Alarm
  • Low Pressure or Engine Failure
  • Life Expectancy
  • Over 10 years with proper maintenance
  • Protection Grade
  • IP55 for Control Panel
  • Pump Body Material
  • Cast Iron or Ductile Iron
  • Starting Method
  • Electric Start with Backup
  • Prime Mover
  • Diesel Engine (varied power ratings)
  • Fuel Tank Capacity
  • 200-500 liters, customizable
 

Diesel Engine Fire Pump Trade Information

  • Minimum Order Quantity
  • 1 Set
  • Supply Ability
  • 1 Set Per Week
  • Delivery Time
  • 7 Days
 

Diesel Engine Fire Pump About



Personalise your fire protection with our invincible Diesel Engine Fire Pump, crafted for exceptional reliability and rarefied performance in industrial and commercial environments. With discount offers awaiting early movers, jump on the opportunity to secure a robust pump featuring a water-cooled diesel engine, cast iron or ductile iron body, and a direct coupled drive. The unit excels with high energy efficiency, corrosion resistance, and noise control at just 85 dB. Suited to large-scale facilities, it provides seamless operation, automatic alarms, and decade-spanning durability-all with customisable capacity, control, and cutting-edge safety compliance.

Versatile Applications for Enhanced Safety

Diesel Engine Fire Pumps are indispensable for protecting warehouses, factories, refineries, commercial complexes, and large-scale industrial plants. Used as a primary firefighting solution, they efficiently drive hydrant and sprinkler systems across Class A, B, and C fire emergencies. Other applications include integration into municipal water supply networks, airport safety installations, and emergency backup for critical infrastructure, ensuring comprehensive risk mitigation wherever bulk fire protection is a necessity.


Global Exports and Competitive Market Value

We offer Diesel Engine Fire Pumps with flexible FOB port options across major Indian harbors, ensuring prompt exports to Asia, Africa, Middle East, and Europe. Our products hold prestigious certifications, meeting demanding international standards for safety and quality. With market value reflecting robust build and superior technology, contact us for current asking prices and discover how our industry-leading solutions and after-sales support can elevate fire safety for your facility.


FAQ's of Diesel Engine Fire Pump:


Q: How does the Diesel Engine Fire Pump ensure reliable operation during a fire emergency?

A: The pump features a direct coupled, water-cooled diesel engine with electric start and backup options, ensuring invincible performance even during power failures. An automatic alarm system monitors for low pressure or engine failure, maximizing reliability when needed most.

Q: What types of fires can this pump system effectively address?

A: This Diesel Engine Fire Pump is designed for effective suppression of Class A, B, and C fires, making it suitable for diverse fire scenarios found in industrial and commercial applications.

Q: Where can the Diesel Engine Fire Pump be installed?

A: The pump is ideal for floor-mounted installations in factories, warehouses, refineries, high-rise buildings, airports, and municipal water systems, thanks to its robust construction and flexible connectivity options.

Q: What is the process for customising the pump's configuration?

A: Customization is straightforward: select from options like suction/discharge size, fuel tank capacity, and pump body material. Our team provides personalised guidance to ensure the pump fits your site's technical and operational needs.

Q: When should regular maintenance be conducted for optimal pump life?

A: To ensure an operational life exceeding ten years, routine maintenance should be scheduled according to the manufacturer's guidelines, typically at six-month intervals or after major deployments.

Q: How does this pump benefit large-scale facility safety systems?

A: Its high efficiency, reliable diesel backup, and advanced integration capability guarantee continuous operation during emergencies, covering wide areas and safeguarding essential infrastructure.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Pump System Category

Main Fire Pum

Main Fire Pum

Price 49500.00 INR / Piece

Minimum Order Quantity : 1 Piece

Fire Class : Suitable for Class A, B, and C fires (depending on installation)

Shape : Horizontal split case, vertical turbine, end suction

Fire Extinguisher Type : Main Fire Pump (not a portable extinguisher)

Coverage Area : Customizable as per requirement

Jockey Fire Pum

Jockey Fire Pum

Minimum Order Quantity : 1 Piece

Fire Class : Class A, B, C (application depends on system design)

Shape : Horizontal

Fire Extinguisher Type : Not applicable (pump for hydrant/sprinkler system)

Coverage Area : Depends on system design